Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1983 1
1987 1
1989 1
1990 1
1992 2
1993 1
1994 2
1995 2
2000 1
2002 1
2003 2
2004 2
2005 1
2007 3
2008 1
2009 2
2010 8
2011 6
2012 5
2013 8
2014 5
2015 9
2016 7
2017 9
2018 8
2019 8
2020 11
2021 13
2022 16
2023 18
2024 5

Text availability

Article attribute

Article type

Publication date

Search Results

151 results

Results by year

Filters applied: . Clear all
Page 1
Showing results for G. perot
Search for G. Perota instead (3 results)
Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement.
Kapadia SR, Makkar R, Leon M, Abdel-Wahab M, Waggoner T, Massberg S, Rottbauer W, Horr S, Sondergaard L, Karha J, Gooley R, Satler L, Stoler RC, Messé SR, Baron SJ, Seeger J, Kodali S, Krishnaswamy A, Thourani VH, Harrington K, Pocock S, Modolo R, Allocco DJ, Meredith IT, Linke A; PROTECTED TAVR Investigators. Kapadia SR, et al. N Engl J Med. 2022 Oct 6;387(14):1253-1263. doi: 10.1056/NEJMoa2204961. Epub 2022 Sep 17. N Engl J Med. 2022. PMID: 36121045 Clinical Trial.
Closed-loop MOEMS accelerometer.
Taghavi M, Abedi A, Parsanasab GM, Rahimi M, Noori M, Nourolahi H, Latifi H. Taghavi M, et al. Opt Express. 2022 Jun 6;30(12):20159-20174. doi: 10.1364/OE.455772. Opt Express. 2022. PMID: 36224767 Free article.
In this paper, a closed-loop micro-opto-electro-mechanical system (MOEMS) accelerometer based on the Fabry-Perot (FP) interferometer is presented. The FP cavity is formed between the end of a cleaved single-mode optical fiber and the cross-section of a proof mass (PM) whic …
In this paper, a closed-loop micro-opto-electro-mechanical system (MOEMS) accelerometer based on the Fabry-Perot (FP) interferometer …
Advances in Multicore Fiber Interferometric Sensors.
Yao Y, Zhao Z, Tang M. Yao Y, et al. Sensors (Basel). 2023 Mar 24;23(7):3436. doi: 10.3390/s23073436. Sensors (Basel). 2023. PMID: 37050498 Free PMC article. Review.
., multiple cores integrated into only one fiber cladding, multicore fiber (MCF) interferometric sensors exhibit many desirable characteristics compared with traditional fiber interferometric sensors based on single-core fibers, such as structural and functional diversity, high i …
., multiple cores integrated into only one fiber cladding, multicore fiber (MCF) interferometric sensors exhibit many desirable characterist …
Recent Progress in MEMS Fiber-Optic Fabry-Perot Pressure Sensors.
Chen Y, Lu D, Xing H, Ding H, Luo J, Liu H, Kong X, Xu F. Chen Y, et al. Sensors (Basel). 2024 Feb 7;24(4):1079. doi: 10.3390/s24041079. Sensors (Basel). 2024. PMID: 38400236 Free PMC article. Review.
Recently microelectromechanical systems (MEMS) fiber-optic Fabry-Perot (FP) pressure sensors have attracted great interest. Here we review the basic principles of MEMS fiber-optic FP pressure sensors and then discuss the sensors based on different materials and their indus …
Recently microelectromechanical systems (MEMS) fiber-optic Fabry-Perot (FP) pressure sensors have attracted great interest. Here we r …
Fabry-Perot interferometry with gate-tunable 3D topological insulator nanowires.
Osca J, Moors K, Sorée B, Serra L. Osca J, et al. Nanotechnology. 2021 Aug 6;32(43). doi: 10.1088/1361-6528/ac1633. Nanotechnology. 2021. PMID: 34284353
Here, we focus on the transport properties of a 3D TI nanowire with a gated section that forms an electronic Fabry-Perot (FP) interferometer that can be tuned to act as a surface-state filter or energy barrier. ...We also consider the interplay of FP interference with an e …
Here, we focus on the transport properties of a 3D TI nanowire with a gated section that forms an electronic Fabry-Perot (FP) interfe …
Miniature tri-axis accelerometer based on fiber optic Fabry-Perot interferometer.
Qu Z, Lu P, Zhang W, Xiong W, Liu D, Zhang J. Qu Z, et al. Opt Express. 2022 Jun 20;30(13):23227-23237. doi: 10.1364/OE.459773. Opt Express. 2022. PMID: 36225008 Free article.
The sensor is composed of a 20 mm diameter spherical outer frame and a three-dimensional spring-mass structure as the inertial sensing element. Three Fabry-Perot interferometers (FPI) are formed between flat fiber facets and cubic mass surfaces to measure the FPI cavity le …
The sensor is composed of a 20 mm diameter spherical outer frame and a three-dimensional spring-mass structure as the inertial sensing eleme …
A Fabry-Perot cavity coupled surface plasmon photodiode for electrical biomolecular sensing.
Allison G, Sana AK, Ogawa Y, Kato H, Ueno K, Misawa H, Hayashi K, Suzuki H. Allison G, et al. Nat Commun. 2021 Nov 10;12(1):6483. doi: 10.1038/s41467-021-26652-7. Nat Commun. 2021. PMID: 34759292 Free PMC article.
The photogenerated current is enhanced due to the coupling of the plasmon mode with Fabry-Perot modes in the absorbing layer of the photovoltaic cell. The near field electrical detection of surface plasmon resonance we demonstrate will enable a next generation of cheap, co …
The photogenerated current is enhanced due to the coupling of the plasmon mode with Fabry-Perot modes in the absorbing layer of the p …
Optical Fibre Pressure Sensors in Medical Applications.
Poeggel S, Tosi D, Duraibabu D, Leen G, McGrath D, Lewis E. Poeggel S, et al. Sensors (Basel). 2015 Jul 15;15(7):17115-48. doi: 10.3390/s150717115. Sensors (Basel). 2015. PMID: 26184228 Free PMC article. Review.
This means that the sensor can be placed directly inside a patient, e.g., for urodynamic and cardiovascular assessment. This paper presents an overview of the recent developments in optical fibre-based pressure measurements with particular reference to these application ar …
This means that the sensor can be placed directly inside a patient, e.g., for urodynamic and cardiovascular assessment. This paper pr …
Vibrant reflective sensors with percolation film Fabry-Perot nanocavities.
Palinski TJ, Tadimety A, Trase I, Vyhnalek BE, Hunter GW, Garmire E, Zhang JXJ. Palinski TJ, et al. Opt Express. 2021 Aug 2;29(16):25000-25010. doi: 10.1364/OE.432097. Opt Express. 2021. PMID: 34614841 Free article.
Dynamically reconfigurable structural colors are promising materials for new smart optical systems. However, improved reflected color quality (e.g., saturation, optical contrast, angular invariance) and larger tuning range/sensitivity are needed. ...Our structure consists …
Dynamically reconfigurable structural colors are promising materials for new smart optical systems. However, improved reflected color qualit …
High-Temperature Fiber-Optic Fabry-Perot Vibration Sensor Based on Single-Crystal Sapphire.
Liu H, Jia P, Su C, Zhao A, Liu J, Ren Q, Xiong J. Liu H, et al. Sensors (Basel). 2023 May 21;23(10):4952. doi: 10.3390/s23104952. Sensors (Basel). 2023. PMID: 37430867 Free PMC article.
In this paper, a fiber-optic Fabry-Perot (F-P) vibration sensor that can work at 800 C is proposed. ...The sensor was prepared by ultraviolet-laser ablation and three-layer direct-bonding technology. Theoretically, the sensor has a sensitivity of 0.883 nm/g and a re …
In this paper, a fiber-optic Fabry-Perot (F-P) vibration sensor that can work at 800 C is proposed. ...The sensor was prepared by ult …
151 results